11.12.2 Continuing Incomplete Upgrade of First Nodes
When the first node cannot be upgraded, use these steps to continue the upgrade process.
If the OUI failure indicated a need to reboot by raising error message CLSRSC-400, then reboot the first node (the node on which you started the upgrade). Otherwise, manually fix or clear the error condition, as reported in the error output.
Log in as an Administrator user on the first node.
Change directory to the new Grid home on the first node, and run the gridconfig.bat —upgrade command on that node again. For example:
C:\> cd app\19.0.0\grid\crs\config\
C:\..\grid> gridconfig.bat -upgrade
Complete the upgrade of all other nodes in the cluster.
Configure a response file, and provide passwords required for the upgrade.
To complete the upgrade, log in to the first node as the Oracle Installation user for Oracle Grid Infrastructure and run the script setup.exe, located in the Grid_home, specifying the response file that you created.
For example, if the response file is named gridinstall.rsp:
C:\> cd Grid_home\crs\config
C:\Grid_home> setup.exe -executeConfigTools -responseFile Grid_home\install\response\gridinstall.rsp
Note:
When you reupgrade Oracle Grid Infrastructure, you must use the
-all flag with the executeConfigTools
command to run all the configuration tools.